Agastat 7012X3CN Industrial Electropneumatic Timing Relay | On-delay Operation | 2PDT (2 form C) Contact Arrangement | Special DC Coils | 1.5 to 15 Seconds Timing Range Simple Type: Electropneumatic Timing Relay
For Resellers and High Volume Orders:
Please request a quote to obtain preferred pricing.
Features
- Auxiliary timed and instantaneous switches can be added for greater switching flexibility
- Available in 2-pole or 4-pole models
- Available in on-delay, true off-delay, and on/off-delay
- Easy-to-reach screw terminals, all on the face of the unit, clearly identified
- Inherent transient immunity
- Many mounting options: Surface mount, Panel mount, Octal plug-in mounting
- Modular assembly - timing head, coil assembly and switch-block are all individual modules, with switches field-replaceable
- Numerous enclosure options: explosion proof, dust tight, watertight, hermetically-sealed, NEMA 1
- Options: quick-connect terminals, dial stops, and transient protection module
- Oversize time-calibrated adjustment knobs, serrated with high-resolution markings visible from all angles makes the timer easy to set timers
- Standard voltages from 6-550VAC and 12-550VDC (special voltages available)
- Timing from 0.1 seconds to 60 minutes, in linear increments
Specifications
- Dielectric: Withstands 1500 volts RMS 60Hz between terminals and ground. 1,000 volts RMS 60 Hz between non-connected terminals
- Power Consumption: Approximately 8 watts power at rated voltage.
- Relay Release Time: 50 msec. for on-delay models
- Repeat Accuracy: For delays of 200 seconds or less: +5%; For delays greater than 200 seconds: +10%
- Reset Time: 50 msec.
- Surge Life: Applied 100,000 times continuously with the interval of 10 seconds at room temperature. Below 68 VAC: 12A; Above 68 VAC: 35A
- Temperature Range: Operating: -22°F to +167°F (-30°C to + 75°C) Storage:-40°F to +167°F (-40°C to +75°C)
- Timing Adjustment: Timing is set by simply turning the dial to the desired time value.
- Timing Specifications: On-delay (delay on pick-up).
Applications
- None Available